A din rail mounted current sensing relay dedicated for dc earth fault monitoring such as insulation deterioration on a dc system.
Dc earth fault relay schneider.
Ground fault relays do not provide overcurrent or sh ort circuit protection.
This can be dangerous to nearby personnel and could result in equipment damage.
Se 601 manual spanish se 601 3d model.
Littelfuse ground fault protection relays offer the needed protection against ground faults.
Let us assume the system dc voltage is 120v.
Dc power systems and stationary battery in switchgear and control applications are typically designed and operated as ungrounded systems which means that there is no intentional low resistance or solid connection to ground from either the positive polarity or negative polarity of the dc system.
Thus leakage current if any will be dependent on the resistance value between respective terminals higher the resistance lower is the leakage.
Ground faults occur when electricity travels an unintentional path between a power source and electrical ground.
Its output relay can operate in the fail safe or non fail safe mode for undervoltage or shunt trip applications.
Dc earth leakage relay responding to a negative or positive earth fault will illuminate the appropriate led on the unit facia indicating precisely which pole is earthed.
What is dc ground fault.
Ground censor ground fault protection system type gc keywords.
Ground censor created date.
The relay senses the dc earth leakage current for any equipments like switch boards rectifiers battery chargers by sensing resistance between positive negative terminals of dc system earth.
The dc earth leakage relay is capable of detecting earth faults on charger rectifiers and transformer secondary as well as.
A vigirex ground fault system includes these components.
Our range encompasses voltage frequency relays earth leakage relays idmt relays diesel engine controllers protections current earth fault relays earth monitoring relays earth leakage monitors voltage stabilizers battery chargers rectifiers and other products.
The se 601 is a microprocessor based ground fault monitor for ungrounded dc systems.
If there is no fault the voltage with respect to earth is equally di.
Vigirex ground fault relay this has control powe r inputs inputs from the sensor outputs to the disconnect device and electronic circuitry that determines if the ground fault exceeds the trip level.
With 14 years of experience in the industry we are able to offer wide range of electrical and electronic products.